QMFZ2 Component - Plastics |
Monday, February 28, 2005 |
E42956 | |||||||
|
HITACHI CHEMICAL CO LTD |
|||||||||
| Material Designation: CP-J-8800, CP-J-NAF, CP-J-F(N) | |||||||||
| Product Description: Phenolic (PF), furnished as granular material, finished parts. | |||||||||
| Color | Min. Thick. (mm) | Flame Class | HWI | HAI | RTI Elec | RTI Imp | RTI Str | IEC GWIT | IEC GWFI |
| BK | 0.16 | V-0 | - | - | 150 | 150 | 150 | - | - |
| BK, BN | 0.38 | V-0 | 0 | 0 | 150 | 150 | 150 | - | - |
| ¡@ | 0.46 | V-0 | 0 | 0 | 150 | 150 | 150 | - | - |
| ¡@ | 0.87 | V-0 | 0 | 0 | 150 | 150 | 150 | - | - |
| ¡@ | 1.6 | V-0 | 0 | 0 | 150 | 150 | 150 | - | - |
| ¡@ | 3.0 | V-0 | 0 | 0 | 150 | 150 | 150 | - | - |
| CTI: 3 | IEC CTI (V): - | HVTR: 0 | D495: 5 | IEC Ball Pressure (¢XC): - | |||||
| Dielectric
Strength (kV/mm): 25 ISO Tensile Strength (MPa): - ISO Tensile Impact (kJ/m2): - |
Volume Resistivity (10xohm-cm):
12 |
Dimensional Stability(%): 0 |
|||||||
| Report Date: 1/8/1987 | Underwriters Laboratories Inc® | ||||||||
|
UL94 small-scale test data does not pertain to building materials, furnishings and related contents. UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in components and parts of end-product devices and appliances, where the acceptability of the combination is determined by ULI. |
|||||||||